Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2005 | FRAMING | Approved | ||
| 10/26/2005 | FRAMING | Denied | 1) GROUND EXTERIOR METAL BOXES 2) MOVE WIRE FROM CAN LIGHT 3) MISSING W/H CONDUCTOR 4) GAS LINE CANNOT BE UNDER BLDG 5) NEED ACCESS PANELS AT J-BOX AND WATER LINE 6) REMOVE EXISTING PORCH LIGHT |
|
| 10/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CROSS BRACE 4 END TRUSSES AND ? 25' ON CENTER 2) INSTALL EXTERIOR LIGHT BOXES 3) BATH GFI OUTLET SHALL BE WIRED WITH 12-2 WIRE WITH NO OTHER FIXTURES-WIRE TO BE INSTALLED PER APPROVED DRAWINGS 4) WATER TEST REQUIRED ON TOP-OUT ? 5) PEX WATER SHALL BE 12" MINIMUM FROM LIGHT CANISTER 6) COMPLETE EXHAUST FAN INSTALLATION 7) REVISE DRAWINGS TO REFLECT AS BUILT 8) NEED GAS LINE LAYOUT APPROVED BY DSD AND PERMITS 9) INSTALL WIRING FOR SMOKE ALARMS 10) STOPPED INSPECTION |
|
| 10/06/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES PRIOR TO FRAME INSPECTION |