Permit: T05CM01065

Parcel: 140060430


Addresses:

5408 S MADISON SV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/07/2005 FRAMING Approved
10/26/2005 FRAMING Denied 1) GROUND EXTERIOR METAL BOXES
2) MOVE WIRE FROM CAN LIGHT
3) MISSING W/H CONDUCTOR
4) GAS LINE CANNOT BE UNDER BLDG
5) NEED ACCESS PANELS AT J-BOX AND WATER LINE
6) REMOVE EXISTING PORCH LIGHT
10/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CROSS BRACE 4 END TRUSSES AND ? 25' ON CENTER
2) INSTALL EXTERIOR LIGHT BOXES
3) BATH GFI OUTLET SHALL BE WIRED WITH 12-2 WIRE WITH NO OTHER FIXTURES-WIRE TO BE INSTALLED PER APPROVED DRAWINGS
4) WATER TEST REQUIRED ON TOP-OUT ?
5) PEX WATER SHALL BE 12" MINIMUM FROM LIGHT CANISTER
6) COMPLETE EXHAUST FAN INSTALLATION
7) REVISE DRAWINGS TO REFLECT AS BUILT
8) NEED GAS LINE LAYOUT APPROVED BY DSD AND PERMITS
9) INSTALL WIRING FOR SMOKE ALARMS
10) STOPPED INSPECTION
10/06/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL TRADES PRIOR TO FRAME INSPECTION