Permit: T05CM01061

Parcel: 111073270


Addresses:

3119 E BERMUDA ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
05/05/2005 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
04/22/2005 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED 1" CLEARANCE FROM B-VENT TO WOOD
04/20/2005 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK VENTS 3 SIDE
2) #1 OF LAST INSPECTION
04/13/2005 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FURNACE B-VENT REQUIRES 1" CLEARANCE TO WOOD COMBUSTIBLES AT ROOF SHEATHING
2) BOND GAS LINE
3) YOU MUST OBTAIN AN ELECTRIC SERVICE RECONNECT PERMIT TO OBTAIN ELECTRIC POWER
4) ELECTRIC SERVICE PANEL REQUIRES TWO EACH 8 FT GROUND RODS 6 FEET APART CONNECTED TO PANEL WITH A CONTINOUSE E4 GROUND WIRE
04/12/2005 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*