Inspection History: FRAMING

Permit Number - T05CM01034

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/27/2005 FRAMING Approved IVRS - Inspection :*
SAME AS LAST INSP. (LATH H20, SURV, T&P) MECH DUCT DRY OUT OF/WALL
07/25/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) MISSED TWO A.B.'S AT WEST SIDE 1ST FLOOR
2) NEED RETRO P.A. AT REAR
3) FLAT VENT TO BE IN UPPER 1/3 OF HORIZONTAL DRAIN
4) #5 SHEAR A.B.'S AT 24" ON CENTER
5) SECURE EAST HOSE BIB
6) 1ST FLOOR BATHROOM NOT COMPLETE (PLUMBING)
7) DRYER VENT OUT OF WALL
8) H20 TEST ON HOT SIDE
9) BLOCK AT 2ND FLOOR BATH STUD OVERSPAN
10) RAT RUN CUT
11) LEAK IN H20 SERVICE AT EXTERIOR WALL AND AT H20 HTR PIPE NOT SECURED AT BOTH LOCATIONS
12) CAULK ALL LATH PENETRATIONS
13) GAS PRESSURE OK