Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* NORTH BEDROOM - 2 GANG SW BOX NEEDS PLASTER RING & SEAL 1/2 KO |
|
| 11/13/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ELECTRICAL COVER INTERIOR OF SOUTH UNIT ONLY. NOTE: MAKE SURE KITCHEN COUNTER RECEPTACLES LAND ABOVE COUNTERTOPS AND NOT BEHIND SINK ETC... |
|
| 10/30/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* INSPECTION OF SOUTH UNIT INTERIOR ONLY 1. RECEPTACLE BOX BY BEDROOM FRENCH DOOR IS OVERFILLED. 2. SMOKE DETECTOR BOX IN NORTH BEDROOM IS OVERFILLED 3. STILL NEED DEDICATED 20 AMP. RECEPTACLE IN BATHROOM 4. WHERE IS FEEDER TO NORTH UNIT? 5. INSTALL NAIL PLATES WHERE HOLE IS LESS THAN 1 1/4" FROM STUD FACE. |
|
| 10/25/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* INSPECTION FOR INTERIOR OF SOUTH UNIT ONLY 1. SMOKE DETECTORS NEED TO BE AT LEAST 36" FROM HVAC VENTS. 2. STAPLE ALL ROMEX WITHIN 8" OF BOXES. 3. IDENTIFY WHITE USED AS HOT IN SWITCH LEG 4. NEED DEDICATED 20 AMP RECEPTACLE IN BATHROOM. 5. FRONT ENTRY THREE GANG BOX -- PROPERLY TERMINATE GROUNDS AND GROUND J-BOX. 6. DAMAGE WIRE TO LIVING LIGHT SWITCH NEEDS TO BE RE-RAN AND RUN DIRECTLY TO SWITCH (NOT WASHER) 7. KITCHEN RECEPTACLES FOR RANGE AND COUNTERTOP ARE NOT PROPERLY LOCATED AT SINK AREA -- SEE PLAN. 8. KITCHEN COUNTER RECEPTACLES CAN'T SERVE OTHER LOADS DISH/DISP/HOOD 9. NEED TWO 20 AMP. CKTS TO FEED KITCHEN COUNTER RECEPTACLE -- SEE PLAN. |
|
| 10/23/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* GATE IS LOCKED |