Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 04/09/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. CLEANOUTS ARE TO BE INSTALLED VERTICALLY, ABOVE THE FLOW LINE OF THE PIPE FURNCO NOT PERMITTED IN WALL 2. STAND PIPES, TRAPS ARE TO BE ROUGHED IN BETWEEN 6"-18" ABOVE FINISHED FLOOR STAND PIPES ARE TO BE BETWEEN 18"-30" LONG 3. ABS MAY NOT BE INSTALLED IN EXPOSED EXTERIOR LOCATION - PAINTED OR NOT |
|
| 04/07/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. DOOR LOCKED - I LEFT A VOICEMAIL AT 270-6003 2. I WALKED AROUND BACK AND NOTICED SOME NEW, PAINTED PIPING. PLEASE NOTE THAT ABS IS NOT PERMITTED IN EXPOSED EXTERIOR LOCATIONS, PAINTED OR NOT. AAV's ARE NOT PERMITTED IN LIEU OF REQUIRED VENTING, NOR ARE THEY PERMITTED IN EXPOSED EXTERIOR LOCATIONS |
|
| 04/04/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/13/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BRING ALL UP TO CODE 2. COMPLETE WORK BEFORE CALLING FOR INSPECTION. |