Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/23/2005 BUILDING - FINAL Approved IVRS - Inspection :*
09/22/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
BRACE FRONT CARPORT
#'S 1, 4, 6, 10 FROM 9/20 NOT CHECKED OFF
09/20/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE OUTLET AND SWITCH COVERS
2) INSTALL FAN COVERS IN HALL BATH
3) CAULK W.C TO FLOOR
4) INSTALL DISHWASHER W/ DRAIN LOOP
5) COMPLETE OUTLET IN ISLAND
6) ANTI-TIP ON STOVE
7) DRIP LEG NEEDED ON WATER HEATER AND FURNACE
8) 1" CLEARANCE TO COMBUSTIBLES AROUND WATER HEATER B-VENT
9) COMPLETE EXTERIOR OUTLET
10) LABEL BREAKERS IN PANEL
11) PAINT PLUMBING VENTS PENETRATING ROOF
12) SECURE GAS LINE @ FURNACE