Permit: T05CM00987

Parcel: 140383520

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/22/2005 FRAMING Approved IVRS - Inspection :*
06/21/2005 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
No dwv water test
Fireblock range hood
Smoke detector cannot be over pot shelf
Pex must be 12" from can lights
You must pay reinspection fee prior to next inspection
06/17/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) COMBUSTIBLE MATERAIL WITHIN 1" OF WATER HEATER B-VENT
2) NO DWV WATER TEST
3) NAIL PROTECT WIRES HALL BATH
4) SECURE AND MAKE UP BATHROOM FAN WIRES PER CODE
5) PLUMBING BELOW CEILING
6) STOPPED INSPECTION
7) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE
06/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO DWV WATER TEST
2) FIREBLOCK RANGE HOOD
3) PEX MUST BE 12" FROM CAN LIGHTS
4) HOLDOWNS MISSING NUTS
5) NAIL PROTECT WIRES HALL BATH (CEILING)
6) SMOKE DETECTORS CANNOT BE OVER POT SHELF
7) PLUMBING BELOW CEILING
8) SECURE AND MAKE UP FAN WIRES
9) W/H B VENT 1" TO ROOFING
10) OK TO INSULATE