Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/21/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection No dwv water test Fireblock range hood Smoke detector cannot be over pot shelf Pex must be 12" from can lights You must pay reinspection fee prior to next inspection |
|
| 06/17/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) COMBUSTIBLE MATERAIL WITHIN 1" OF WATER HEATER B-VENT 2) NO DWV WATER TEST 3) NAIL PROTECT WIRES HALL BATH 4) SECURE AND MAKE UP BATHROOM FAN WIRES PER CODE 5) PLUMBING BELOW CEILING 6) STOPPED INSPECTION 7) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE |
|
| 06/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO DWV WATER TEST 2) FIREBLOCK RANGE HOOD 3) PEX MUST BE 12" FROM CAN LIGHTS 4) HOLDOWNS MISSING NUTS 5) NAIL PROTECT WIRES HALL BATH (CEILING) 6) SMOKE DETECTORS CANNOT BE OVER POT SHELF 7) PLUMBING BELOW CEILING 8) SECURE AND MAKE UP FAN WIRES 9) W/H B VENT 1" TO ROOFING 10) OK TO INSULATE |