Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 05/06/2005 | BUILDING - FINAL | Partial Approval | 1) ROOF CONSTRUCTION AT REAR PORCH, 2 X 4 RAFTERS 24" ON CENTER NOT PER CODE. HAVE DRAWING APPROVED 2) RELATE LAST INSPECTION TO PREVIOUS INSPECTOR |
|
| 05/05/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ANSWER AT FRONT DOOR 2) PLEASE RECALL |
|
| 04/14/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER WIRE SHALL BE PROTECTED 2) VACCUM BREAKERS AT HOSE BIBBS SHALL BE WITH PERMANENT SET SCREW 3) EXISITING ROOF AT REAR PORCH IS A HAZARD WILL NOT WITHSTAND A 20 LB LIVE LOAD PER ? FT. |
|
| 03/11/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GFI IN KITCHEN DOES NOT TEST 2) PRESSURE RELIEF VALVE AT WATER HEATER MUST BE EXTENDED TO EXTERIOR 6"-24" ABOVE GROUND WITH 90 FITTING POINTING TOWARDS GROUND 3) SMOKE DETECTOR DOES NOT TEST. SMOKE DETECTOR NOT LABELED ON PLANS 4) INSTALL ANTI-SIPHON ON ALL HOSE BIBS 5) PAINT ROOF VENTS 6) MAIN SERVICE PANEL DBL LUGGED 15 AMP BREAKER. LABEL ALL CIRCUITS. NO SPLICES ALLOWED IN SERVICE TO HOT LEADS. ALL HOLT LEADS MUST BE RED OR BLACK 7) REVISE PLAN TO SHOW PATIO COVER 8) ALL ROMEX AT PATIO COVER UNDER 8' MUST BE PROPERLY COVERED 9) PROPER HARDWARE NEEDED AT ALL PATIO COVER CONNECTIONS |