Permit: T05CM00968

Parcel: 140378060

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM00968

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/10/2005 FRAMING Approved IVRS - Inspection :*
11/09/2005 FRAMING Cancelled CANCELLED PER TIM (SUPER) OF K.B. HOMES #907-6040
11/09/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
11/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE 1" CLEARANCE TO COMBUSTIBLE MATERIAL AT WATER HEATER VENT
2) PEX MUST BE 6" FROM WATER HEATER "B" VENT
3) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE
11/03/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) FIREBLOCK CHASE AT GARAGE
2) PROVIDE 1" CLEARANCE TO COMBUSTION AT WATER HEATER
3) RENAIL GARAGE SHEARWALL SHINERS
4) PEX MUST BE 6" FROM 'B' VENTS
5) PONY WALL AT STAIR MUST SUPPORT 200 POUNDS
6) MAXIMUM ALLOWED BULL NOSE ON STAIRS 1" PER 50/AD3
7) STOPPED INSPECTION-TO MANY ITEMS
8) NEXT FAILURE WILL REQUIRE REFEE BE IMPOSED
11/01/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) PORCH POURED WITHOUT APPROVAL-PROVIDE PROOF THAT FOOTINGS ARE 18" BELOW GRADE PER 6A/SD1-SCHEDULE INSPECTION
2) SCHEDULE ROOF AND STUCCO LATH INSPECTION
3) MOVE BLDG MATERIAL AWAY FROM WALLS FOR INSPECTION
4) PROVIDE RETRO ANCHOR BOLTS PER ? ENGINEERING LETTER
5) ANCHOR BOLTS LOOSE
6) PEX CANNOT BE WITHIN 6" OF 'B' VENT
7) WATER HEATER 'B' VENT MUST BE 1" TO COMBUSTIBLE
8) LSU26 HANGERS MISSING AT STAIRS
9) STAIR STRINGERS NOT NAILED
10) SUPPORT LSL
11) STOPPED INSPECTION
10/27/2005 FRAMING Not ready for Inspection IVRS - Inspection :*