Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM00968
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
09/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE SURFACE 2) SECOND FLOOR P-1 SHEARWALL NOT INSTALLED 3) TWO ANCHOR BOLTS REQUIRED ON PLATES FOR ENTRY COLUMN 4) WRONG PLANS ON SITE 5) NO LADDER ACCESS 6) NO TRUSS DRAWINGS ON SITE |