Permit: T05CM00964

Parcel: 140294570

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM00964

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/20/2005 FRAMING Approved IVRS - Inspection :*
05/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OVERSPAN BETWEEN C1 AND C2 TRUSS
2) EXTEND DRYER VENT ABOVE ROOF LINE
3) LTH5R HANGERS MISSING NAILS
4) 10SD4 NOT PER PLAN
5) CLEANOUTS AND VENTS NOT PER PLAN
6) OVERSPAN EAST WALL
7) SHIM HEADERS
8) NAIL PROTECT WATER LINES AT KITCHEN PONY WALL
9) STOPPED INSPECTION ANS SEE LAST INSPECTION
05/13/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) BANG PLATE H20 SERV. TOP PLATE
2) FILL ALL NAIL HOLES HIP HANGERS GARAGE
3) A.B. AT GARAGE COMB. VENT
4) NO H20 IN DWV SYSTEM
5) ZERO GAS PRESSURE
6) A.B. SPACING FOR P-1 SHEAR GARAGE TO HOUSE ?
7) 12" CLEARANCE PEX TO CAN LIGHTS, KITCHEN FRONT CLOSET
8) BANG PLATE A/C LINES AND A/C ROMEX REAR WALL. ROMEX AT CLOSET DOOR MASTER
9) BACKING AT KITCHEN PONY WALL BOTH ENDS
10) USE 16D SINKERS REAR PORCH HARDWARE
11) BOWED STUDS GARAGE ?