Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 10/05/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL LUGGING OF #4 AND #6 WIRES ON SAME LUG NOT ALLOWED 2) DRYER FLAP INOPERABLE 3) PARTIALLY ENCLOSED LIGHT BULB FIXTURE IN CLOTHES CLOSET NOT ALLOWED IRC 3903.11 4) PROVIDE DOCUMENTED PROOF THAT GARAGE MAN DOOR IS 20 MINUTE FIRE RATED 5) GARAGE PERSONEL DOOR MUST BE SELF CLOSING/LATCHING 6) NO HAND RAIL 7) BEDROOM SMOKE DETECTORS MUST BE ON AN ARC FAULT PROTECTED ? 8) MAXIMUM ? OF ELECTRIC DEVICES ALLOWED ON 15 AMP ARC FAULT BREAKER IS 13 EXCEEDED 9) FURNACE SPARK SHIELD APPEARS TO BE IMPROPERLY INSTALLED. PROVIDE MANUFACTURERS INSTALLATION MANUAL 10) INADEQUATE INSULATION ONLY 5" INSTALLED EAST SIDE OF FURNACE 11) FURNACE COVERS NON REMOVABLE DUE TO PAN STRAPS 12) NORTH A/C COVER DOES NOT FIT 13) SECONDARY DRAIN PANS FULL OF TRASH 14) DRYER VENT BROKEN |