Permit: T05CM00951

Parcel: 116041240

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/15/2006 BUILDING - FINAL Approved IVRS - Inspection :*
02/21/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE GRADING
2) A/C UNIT OVER FUSED
3) PLUG OPEN KNOCKOUT IN A/C DISCONNECT
4) ARC FAULT BREAKERS REQUIRED ON BEDROOM CIRCUITS
5) PLUG OPEN KNOCKOUTS IN SERVICE PANEL
6) GFI OUTLETS REQUIRED IN KITCHEN
7) CLAMP WATER HTR WHIP 12" FROM J-BOX
8) INTER-CONNECT SMOKIES
9) COMPLETE LIGHT FIXTURES MASTER CLOSETS
10) GROUT SHOWER
11) DBL WALL REQUIRED WITHIN 6" OF COMB
02/15/2006 BUILDING - FINAL Not ready for Inspection 1) OK TO BACKFILL SEPTIC TANK AND SEWER LINE