Permit: T05CM00944

Parcel: 141015490


Addresses:

10621 E CERULEAN WY


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T05CM00944

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/21/2005 BUILDING - FINAL Approved IVRS - Inspection :*
10/20/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST TENSION TAG
2) DAMAGED CONDUCTORS DUE TO OVER TIGHTENING IN PANEL-CHECK ALL
3) T & P LINE FROM WATER HEATER TO RESTRICTIVE
4) 4 OUTLETS IN LIVING ROOM HAVE REVERSED POLARITY
5) MED. CABINET IN M. BATH
6) SMOKIE REQUIRED IN TILED BEDROOM