Permit: T05CM00944

Parcel: 141015490


Addresses:

10621 E CERULEAN WY


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM00944

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/23/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/20/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/PERMIT
05/11/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WIND BRACING SPLICES TO LAP (3 STUDS) (2 BAYS)
2) WIND BRACING TO HAVE 2 NAILS TOP AND BOTTOM
3) STRAP EXTERIOR BOTTOM PLATES AT PLUMBING CUTS
4) SHEARWALLS TO HAVE DBL STUDS EACH END
5) NEED LADDER FOR ROOF INSPECTION
6) NEED TRUSS DRAWINGS
7) STOPPED INSPECTION