Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLTS/PINS NOT INSTALLED P-2 SHEARWALL UNDER STAIRS 2) HOLDOWN NOT INSTALLED 3) DOOR BELL TRANSFORMER CANNOT BE IN ATTIC 4) NO 2ND FLOOR DWV WATER TEST 5) SEAL MECHANICAL CHASE TOP PLATE 2ND FLOOR 6) ELECTRIC OUTLET REQUIRED 2ND FLOOR STAIR LANDING 7) SEAL 2ND FLOOR PENETRATIONS |
|
| 06/20/2005 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) NO PLANS/PERMIT ON SITE |
|
| 06/17/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JOE |