Permit: T05CM00927

Parcel: 140377350


Addresses:

6913 S WINGBOW DR

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
06/14/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
06/02/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE P-2 SHEAR REQUIRES A.B.'S AT 16" ON CENTER
2) NAIL P-2 SHEAR AT 4" ON CENTER
3) KITCHEN G-3 SHEAR NOT ANCHORED PER SHEET S-1
4) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES M/CLOSET
5) FIREBLOCK REQUIRES 2 LAYERS 1/2" OR 1 LAYER 3/4 OSB M/CLOSET
6) A/C CONDENSATE NOT COMPLETE
7) FIRESTOP 2ND FLOOR B/R AT PORCH LID
9) FIREBLOCK GARAGE ROOF AT EAST BEDROOM
10) NAIL PROTECT WIRES AT STAIR
11) OK TO INSULATE AND STOCK