Permit: T05CM00921

Parcel: 123053680

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
10/20/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
03/29/2006 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
12/02/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/28/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TERMINATE POWDER EXHAUST TO EXTERIOR
2) FIREBLOCK POWDER DROPPED CEILING
3) NAIL PROTECT POWDER ROOM DRAIN
4) FIREBLOCK LAUNDRY DROP
5) BLOCK REGISTERS 3-SIDES
6) FIREBLOCK DROPPED CEILING SOUTHWEST BEDROOM CLOSET
7) RELOCATE SD BOTH BEDROOMS MINIMUM 36" FROM REGISTER
8) ALL LUMBER AT GROUND MUST BE TREATED
9) FIREBLOCK ALL DROPPED CEILING
10) TERMINATE BATH EXHAUST TO EXTERIOR
11) GROUND ALL METAL BOXES
06/08/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) REWIRE OF 2 EXISTING BEDROOMS OK TO COVER WALLS AND UNDER ROOF. NEW WIRING FROM PANEL TO EXISTING AND OTHER REMODEL IN LAY-UP 2 X6" ON ROOF NOT INSPECTED YET (DO NOT COVER)