Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/29/2006 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 12/02/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 11/28/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TERMINATE POWDER EXHAUST TO EXTERIOR 2) FIREBLOCK POWDER DROPPED CEILING 3) NAIL PROTECT POWDER ROOM DRAIN 4) FIREBLOCK LAUNDRY DROP 5) BLOCK REGISTERS 3-SIDES 6) FIREBLOCK DROPPED CEILING SOUTHWEST BEDROOM CLOSET 7) RELOCATE SD BOTH BEDROOMS MINIMUM 36" FROM REGISTER 8) ALL LUMBER AT GROUND MUST BE TREATED 9) FIREBLOCK ALL DROPPED CEILING 10) TERMINATE BATH EXHAUST TO EXTERIOR 11) GROUND ALL METAL BOXES |
|
| 06/08/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) REWIRE OF 2 EXISTING BEDROOMS OK TO COVER WALLS AND UNDER ROOF. NEW WIRING FROM PANEL TO EXISTING AND OTHER REMODEL IN LAY-UP 2 X6" ON ROOF NOT INSPECTED YET (DO NOT COVER) |