Permit: T05CM00898

Parcel: 140376130


Addresses:

6895 S GOSHAWK DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/13/2005 BUILDING - FINAL Approved IVRS - Inspection :*
09/02/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ACCESS TO AC CONDENSOR DISCONNECT BLOCKED BY UNIT PROVIDE 30" X 30" UNRESTRICTED ACCESS
2) CONVENIOLLE? OUTLET REQUIRED WITHIN 6 FEET OF WALL END
3) FURNACE "B" VENT NOT CONNECTED TO SIMPLE WALL CONNECTOR WITH 3 EQUALLY SPACED SCREWS
4) FURNACE VENT HAS REVERSE PITCH AT ELBOW
5) REPAIR DRY WALL PATCHES THROUGHOUT