Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T05CM00887
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/12/2006 | MECHANICAL - INTERMEDIATE | Approved | PROVIDE SCREENS IN ROOF VENTS. EXTEND CONDENSATE DRAINS TO WITHIN 6" OF GRADE. TERMINATE WITH AN ELBOW & NIPPLE. REMOVE SCREWS FROM DRYER VENTS. USE RIVETS IF NECESSARY. NO TAPE OUTDOORS. EXTEND WATER HEATER VENTS 2' ABOVE COMBUSTION AIR INTAKE ON ROOF. FURNACE VENTS ARE ABANDONED. PROVIDE MIN 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR. PROVIDE A HIGH COMBUSTION AIR VENT. PROVIDE PLATE STRAPS IN LAUNDRY ROOMS. |