Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T05CM00884
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/10/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*OK WALLS IN UNITS-CHECK INSIDE NEW 6 PACK SERVICE | |
10/18/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*DO NOT USE WATER SYSTEM AS AN EQUIP GROUND TO GROUND SUB PANELS.RUN EQUIP GROUND TO SERVICE AS INDICATED ON PLAN. UNITS TO BE METERED INDIVIDUALLY, BOND WATER PIPING EACH UNIT/ ISOLATE NEUTRALS & GROUNDS IN SUB PANELS COMPLETE CABLE TERMINATIONS AT ALL UNITS. OUTSIDE ENTRY LIGHTS MUST HAVE PRO?? J-BOX FOR TERMINATION |