Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM00880

Parcel: 121101020


Addresses:

4832 E HAMPTON ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM00880

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2006 FRAMING Approved IVRS - Inspection :*
10/18/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NUMBERS 3, 5 & 8 FROM PREVIOUS INSPECTION
05/16/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
03/21/2006 FRAMING Not ready for Inspection IVRS - Inspection :*