Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM00869
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/12/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/06/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL INSULATION ON HOT AND HOT RETURN PIPING AT WATER HEATER 2) INSTALL ALL CLEANOUT COVERS 3) EXPOSE BLDG H20 SERVICE VALVE 4) SEAL ALL PIPE PENETRATIONS INTO BLDG 5) SECURE WATER HEATER EXPANSION TANK. PLEASE HAVE YELLOW PERMIT CARD ON SITE. WOULD LIKE TO SEE REVISED APPROVED PLAN OF ADDITION OF SINK IN ROOM 56 |
|
| 09/01/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* FINISH INSTALLING ALL FIXTURES AND WATER HEATER |