Permit: T05CM00864

Parcel: 140383530

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/18/2005 BUILDING - FINAL Approved IVRS - Inspection :*
08/17/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) NEED INSULATION CERTIFICATES
08/15/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL LUGGING OF STRANDED AND SOLID ? WIRES NOT ALLOWED
2) ELECTRIC SERVICE REQUIRES NON WATER BOND LABEL
3) SECURE A/C WHIP WITHIN 12" OF DISCONNECT
4) MAX ALLOWED FUSE FOR A/C 35 AMP-40 INSTALLED
5) FURNACE ANTI-SPARK SHIELD MISSING. PROVIDE FURNACE INSTALLATION INSTRUCTIONS
08/12/2005 BUILDING - FINAL Cancelled IVRS - RI canceled