Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2005 | FRAMING | Approved | IVRS - Inspection :* 1) RE-INSPECT |
|
| 06/28/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) SHEARWALL 6 REQUIRES EDGE NAILING AT 4" ON CENTER 2) NO DWV WATER TEST 3) BLOCK DEFUSER BOLTS 3 SIDES 4) SHEARWALL NOT CLIPPED PER 10/DT1 5) RED HEAD ANCHOR BOLTS LOOSE 6) STUCCO LATH NOT COMPLETE 7) RE-ROUTE CONDENSATES 8) SHIM HEADERS LEVEL 9) SHEARWALL 7 REQUIRES 5/8" ANCHOR BOLTS AT 24" ON CENTER 10) 3/4" RED HEAD WEDGE ANCHORS NOT ALLOWED WITHIN 7 1/2" OF SLAB EDGE 11) MISSING RANGE HOOD 12) WHERE IS A/C COPPER 13) MISSING HOLDOWN BOLTS 14) STOPPED INSPECTION |