Permit: T05CM00862

Parcel: 140383870

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
06/14/2005 ROOF NAILING Approved IVRS - Inspection :*
06/10/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS
06/07/2005 ROOF NAILING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
6/DT1 not complied with-required at 48" on center
Nails/staples must be at least 3/8" from o.s.b. panel ends and edges
06/06/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MANY ROOF PANELS LOOSE-NOT NAILED OR SHINERS
2) 6/DT1 NOT COMPLIED WITH 48" ON CENTER
3) NAIL BIRD BOARDS AT 6" ON CENTER PER 7/DT1
06/03/2005 ROOF NAILING Denied IVRS - Inspection :
Roof decking is not nailed per plan.| 140*
1) NO CHANGE FROM 6/2/05 INSPECTION, NEXT FAILURE WILL BE CHARGED A REFEE
06/02/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF SHEATHING NOT NAILED TO TRUSSES-MANY LOCATIONS
2) GABLE END BRACES NOT NAILED THRU SHEATHING 6/DT1
3) BIRD BOARDS NOT NAILED THRU SHEATHING PER 7/DT1