Inspection History: ELECTRIC - FINAL

Permit Number - T05CM00839

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/31/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
OK FINAL
03/24/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
OK UNIT 449
UNIT 348 --
1. NEW SWITCHES TO BE GROUNDED
2. INSTALL DISHWASHER CORD
3. FILL UNUSED OPENING AND PROTECT CONDUCTORS AT BATH LIGHT - INSTALL AS PER MANUFACTURERS INSTRUCTIONS.
4. CLOSET LIGHT TO BE LOCATED AS PER 410.8
5. SMOKE DETECTOR TO BE 3' FROM DUCT.
6. CLEAN EXCESS FOREIGN MATERIAL FROM BOSS AND TERMINALS AT SUB PANEL.
7. CORRECTLY IDENTIFY UNGROUNDED CONDUCTORS
8. CONDUCTOR AMPACITY TO BE FOR NM CALBES AS PER 330.80
9. FINISH PREVIOUS ITEM #1
03/22/2006 ELECTRIC - FINAL Cancelled IVRS - RI canceled
03/19/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) AN APPROVED EXTENDER RING IS NEEDED FOR BOXES MORE THAN 1/4" FROM BOX TO SURFACE AT NON COMBUSTIBLES OR FLUSH AT COMBUSTIBLES
2) INSTALL RANGE AND PLUG
12/30/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
12/02/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :* UNIT 347. INSTALL OUTSIDE LIGHT ALSO USE LISTED SPLICE CONNECTIONS FOR ALUMINUM
SET TOILETS.