Permit: T05CM00837

Parcel: 112061240

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/25/2005 FRAMING Approved IVRS - Inspection :*
03/24/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
03/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK REGISTER 3-SIDES
2) COMPLETE SOFFIT
3) ALL FRAMING ? GROUND MUST BE TREATED LUMBER
4) NAIL PROTECT ROMEX TOP PLATE SOUTH BATH WALL
5) NAIL PROTECT COPPER LINES SOUTH WALL
6) REGISTER IS TO RESTRICTED ABOVE CLOSET
7) DBL TOP PLATE NORTH EXTERIOR WALL OVER KNOTCHED. PROVIDE 16 GUAGE STRAPS BOTH PLATES WITH 8 16D NAILS EACH SIDE
8) BLOCK HI-LO VETNS FOR COMBUSTION
9) OVERKNOTCHED STUD AT SHOWER DIVERTER INSTALL SISTER STUD
10) BLOCK SHOWER SURROUND
11) H2.5'S MUST HAVE N AIL EVERY HOLE