Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM00834

Parcel: 10808001B

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/23/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) TRENCH DRAIN OK
OK FOR CONCRETE
08/17/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) 4" AND 6" BACKWATER VALVES OK TO COVER
2) ABS DWV BLDG DRAIN OK-WATER TEST TO 10 FT OK
3) INTERCEPTOR OK-NOT CONNECTED TO SEWER-PER PLAN
4) WILL NEED TO SEE TRENCH DRAIN PRE-POUR
08/16/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*NOT READY FOR INSP UNABLE TO LOCATE PLANS OR PERMITS