Permit: T05CM00825

Parcel: 115023030


Addresses:

439 E LINDEN ST #01


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM00825

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/16/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* 1) CONTRACTOR TO ADD HANGERS AS REQUIRED. 2) PVC DWV THRU ROOF OK.WATER TEST OK. 3) PEX OK. 4) CLOSET FLANGES OK TUBS OK 5) OK TO COVER ALL AREAS.
06/15/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* 1) BRANCHES AS WELL AS MAIN REQUIRE SUPPORTS WE DO NOT ACCEPT SUPPORTS ON THE FITTINGS. ONE MORE TIME: CHANGE OF DIRECTION. CHANGE OF ELEVATION. END OF BRANCHES- THEN NO MORE THAN FOUR FEET BETWEEN HANGERS. 2) PROVIDE MID STORY SUPPORT ON VERTICAL PIPING 3) ALL PIPPING TO BE IN THE WALL.