Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/16/2005 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* 1) CONTRACTOR TO ADD HANGERS AS REQUIRED. 2) PVC DWV THRU ROOF OK.WATER TEST OK. 3) PEX OK. 4) CLOSET FLANGES OK TUBS OK 5) OK TO COVER ALL AREAS. |
| 06/15/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* 1) BRANCHES AS WELL AS MAIN REQUIRE SUPPORTS WE DO NOT ACCEPT SUPPORTS ON THE FITTINGS. ONE MORE TIME: CHANGE OF DIRECTION. CHANGE OF ELEVATION. END OF BRANCHES- THEN NO MORE THAN FOUR FEET BETWEEN HANGERS. 2) PROVIDE MID STORY SUPPORT ON VERTICAL PIPING 3) ALL PIPPING TO BE IN THE WALL. |