Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM00825
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/16/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) CONTRACTOR TO ADD HANGERS AS REQUIRED. 2) PVC DWV THRU ROOF OK.WATER TEST OK. 3) PEX OK. 4) CLOSET FLANGES OK TUBS OK 5) OK TO COVER ALL AREAS. | |
06/15/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) BRANCHES AS WELL AS MAIN REQUIRE SUPPORTS WE DO NOT ACCEPT SUPPORTS ON THE FITTINGS. ONE MORE TIME: CHANGE OF DIRECTION. CHANGE OF ELEVATION. END OF BRANCHES- THEN NO MORE THAN FOUR FEET BETWEEN HANGERS. 2) PROVIDE MID STORY SUPPORT ON VERTICAL PIPING 3) ALL PIPPING TO BE IN THE WALL. |