Permit: T05CM00824

Parcel: 115023030


Addresses:

441 E LINDEN ST #01


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM00824

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/27/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* 1) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 2) TRAP ARM MAY NOT CHANGE SIZE. TRAP TO BE SAME SIZE AS TRAP ARM. TRAP TO BE ONLY ONE PIPE SIZE LARGER THAN TAILPIECE. 3) OK TO COVER ALL AREAS.
06/23/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :* NORTH UNIT UP STAIRS & DOWN STAIRS PARTIAL APPROVAL WASTE VENT & H20 PIPING OK. EXCEPT 1 ST FLOOR RET ROOM OK FOR POUR BACK 1) NEED TO VIEW TUB & TUB SHOWER VALVE INSTALL WITH TEST. AT 1ST FLOOR STAIR WELL AREA. SOUTH UNIT REPAIR LEAK ON 3" WASTE RISER TO 2ND FLOOR. 2) ALL HOT & COLD H20 PIPING REQUIRES SEPARATION PER MANUFACTURERS INSTALLATION INST.