Permit: T05CM00815

Parcel: 140295420

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM00815

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/23/2005 FRAMING Approved IVRS - Inspection :*
05/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER LINES NEED 12" CLEARANCE FROM CAN LIGHTS
2) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR
3) HTT 16 MISSING EPOXY BOLT
4) PATIO HANGERS MISSING NAILS AND USE CORRECT NAILS PER MANUFACTURER
5) OVERSPAN NORTH WEST WALL
6) DWV TEST NOT HOLDING
7) W/H CHASE NOT FRAMED
8) BLOWN FIRE BLOCK AT SOUTH WEST BEDROOM
9) CAN LIGHT TOUCHING OSB UPSTAIRS HALL PROVIDE MANUFACTURER INSTRUCTIONS FOR CLEARANCE FROM COMBUSTIBLES
10) DBL TOP PLATE AT BALLOON WALL NOT STAGGERED
11) STOPPED INSPECTION