Permit: T05CM00800

Parcel: 110121000


Addresses:

5166 E GLENN ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/03/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/07/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :* 1) PLEASE PROVIDE A LETTER FOR DELETION OF FRONT GFI. OK TEMP C OF O SUBJECT TO DETERMINATION OF INSPECTIONS MANAGER.
07/05/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) BOXES MORE THAN 1/4" FROM BOX TO SURFACE TO USE AN APPROVED EXTENDER RING 314.20. 2) CORRECTLY IDENTIFY UNGROUNDED CONDUCTOR 200.7 3) INSTALL ALL DEVICES. 4) MAINTAIN WORKING CLEARANCE WATER HEATER DISCONNECT. 5) EIT LIGHTING NOT FULLY FUNCTIONAL. 6) FINISH LIGHTING AT SUB PANEL. 7) THIS HAS BEEN AN UNNECESSARY INSPECTION AS DISCUSSED_ A REFEE HAS BEEN ASSESED.