Permit: T05CM00747

Parcel: 140050490


Addresses:

3640 E FELIX BL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM00747

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/17/2005 FRAMING Approved IVRS - Inspection :*
05/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) A.B. LOOSE THROUGHOUT
2) LEAK AT PLUMBING IN CEILING
05/13/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) DROP CEILING H20 HTR, FLUE TO HIGH
2) NEED FULL NUT H.D.'S GARAGE FRONT
3) NO H20 ON DWV TEST
4) 2ND FLOOR BATH, MUST BE 6" ABOVE FLOOD RIM OF FIXTURE SECURED BEFORE GOING HORIZONTAL WITH VENT, NEED MORE PITCH 45 DEGREE IS VERTICAL
5) KITCHEN TO DEN SHEAR TIE TRANSFER TO FLOOR TRUSSES, NO DETAIL FOR LADDER BLKS
6) BANG PLATE ROMEX DEN
7) LOOSE H20 LINES AT 2ND FLOOR SHOWER
8) BRING DBL STUD DOWN, BETWEEN FLOOR TO FLOOR
9) FINISH LATH
10) GAS/PRESSURE-OK/H20 OK