Permit: T05CM00703

Parcel: 112017960

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/30/2005 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/21/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KITCHEN GFCI CIRCUIT 17 DOES NOT TEST
2) INSTALL STOVE ANTI-TILT
3) SEAL WATER CLOSET BASES
4) DINING ROOM CIRCUIT TESTS OPEN GROUND
5) SUITE 2 OUTLETS MUST BE ARC FAULT
6) PROVIDE COVERS FOR CLOSET CANS
7) PANTRY CAN MINIMUM 6" COMBUSTIBLE STACKABLES
11/17/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) WATER HEATER B-VENT OPENING CANNOT BE TAPED OFF
2) AIR MUST BE ABLE TO CIRCULATE BETWEEN INSIDE AND OUTSIDE LAYERS OF B-VENT
08/22/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*