Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/06/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) LATH NOT STAPLED 2) GARAGE SW 7 NOT NAILED PER PLAN 3) WIRING OUT OF WALL CAVITY 4) STOPPED INSPECTION 5) HOUSE NOT COMPLETE ENOUGHT TO INSPECT |
|
| 06/02/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) LATH NOT STAPLED 2) GARAGE SHEARWALL 7 NOT NAILED PER PLAN 3" ON CENTER 3) SHEARWALL 7 REQUIRES A35 CLIPS AT 8" ON CENTER 4) SHEARWALL 7 REQUIRES ANCHOR BOLTS AT 24" ON CENTER 5) SHIM HEADER 6) REPLACE BEARING STUDS NOTCHED MORE THAN 25 PERCENT 7) A/C AND 220 TO FAR APART 8) SEAL ALL VAPOR BARRIER PENETRATIONS 9) FIRESTOP REQUIRES 2 LAYERS OF 1/2" OSB 10) MANY ANCHOR BOLTS LOOSE 11) BEDROOM 2 REQUIRES 2-2 X 10 HEADER 12) STOPPED INSPECTION TO MANY ITEMS |