Inspection History Details
Inspection Status: Partial Approval
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T05CM00658
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Partial Approval
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/06/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PIPE STANDS OK IN VAULT. PLEASE ASK ENGINEER ABOUT SPACING OF STANDS; HAS HE TAKEN FLEX CONNECTOR INTO CONSIDERATION |
|
| 01/10/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) NORTH WALL CENTER SECTION OK TO CLOSE AND POUR |
|
| 01/04/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) OK TO CLSOE AND POUR MIDDLE SECTIONS OF VALVE VAULT 2) SUMP PIT PER ?K1 IS LACKING CONTINUITY OF HORIZONTALS. I HAVE MET WITH SPECIAL INSPECTOR AND HE MAY CONFIRM CORRECTION 3) OK TO PLACE CONCRETE WHEN SP. INSP. CONFIRMS CORRECTION |
|
| 12/23/2005 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :*EAST WALL WITH 10' TURN BACK OK TO CLOSE AND PLACE CONCRETE |
|
| 12/09/2005 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) WEST WALL PROVIDE 4 EXTRA BARS A SOUTH OPENING 2) PROVIDE PROPER CLEARANCE #10 VERTS ON SOUTH SIDE OF NORTH VALVE 3) OK TO POUR WHEN SPECIAL INSPECTOR CONFIRMS |
|
| 11/18/2005 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :*BOTTOM OF VALVE VAULT OK | |
| 10/18/2005 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :*CALL WHEN FOOTINGS FOR VAULT ARE READY TO BE INSPECTED. |