Permit: T05CM00619

Parcel: 114480880

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/26/2005 FRAMING Approved IVRS - Inspection :*
05/26/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NEED TO FINISH WINDOW AND CAULKING
05/24/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE OVER BORED STUDS UNDER MICRO LAM AT LOFT
2) 3RD TRIMMER AT UNDER STAIR CLOSET
3) SECURE 4 GANG IN DINING
4) SHIM 2 X POST UNDER MICRO SOUTH OF STRINGER
05/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*