Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM00586
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/15/2005 | FRAMING | Approved | IVRS - Inspection :* | |
06/13/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ITEM 6 AND 7 FROM 6/7/05 NOT DONE 2) OK TO INSULATE |
|
06/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLT MISSING GARAGE EAST WALL 2) NAIL PROTECT PLUMBING AND ELECTRIC KITCHEN 3) FIREBLOCK SOFFIT AT KITCHEN 4) MAKE UP WIRES IN HALL BATH SWITCH BOX 5) M/BATH EXHAUST FAN NOT IN 6) FIRESTOP HALL ARCH 7) PROVIDE 2 X 4 THRUST BLOCKS BETWEEN LADDER BACK AT 1/D3 8) MECHANICAL NOT COMPLETE 9) T6 TRUSSES REQUIRE TRUSS BRACE RAT RUN |
|
05/31/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER MARK |