Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM00585
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/20/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
07/19/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
07/14/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LABEL SMOKE DETECTOR CIRCUIT IN PANEL 2) 4" CLEARANCE REQUIRED BETWEEN WEEP SCREED AND SOIL 3) ACCESS TO A/C DISCONNECT OBSTRUCTED BY UNIT. MUST HAVE 30' X 30" UN-OBSTRUCTED ACCESS 4) SAFETY GLASS REQUIRED WITHIN 24" OF DOOR OPENING 5) 110 VOLT A/C BEDROOM SMOKE DETECTORS MUST BE ARC FAULT PROTECTED |