Permit: T05CM00585

Parcel: 140324850

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T05CM00585

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/20/2005 BUILDING - FINAL Approved IVRS - Inspection :*
07/19/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/14/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LABEL SMOKE DETECTOR CIRCUIT IN PANEL
2) 4" CLEARANCE REQUIRED BETWEEN WEEP SCREED AND SOIL
3) ACCESS TO A/C DISCONNECT OBSTRUCTED BY UNIT. MUST HAVE 30' X 30" UN-OBSTRUCTED ACCESS
4) SAFETY GLASS REQUIRED WITHIN 24" OF DOOR OPENING
5) 110 VOLT A/C BEDROOM SMOKE DETECTORS MUST BE ARC FAULT PROTECTED