Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T05CM00578
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2005 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 10/03/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/02/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 09/20/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK CHASE AT GARAGE 2) FIRE BLOCK MISSING AT GARAGE WALL 3) DRYER VENT EXCEEDS 25' FT RUN 4) FIRE BLOCK CHANNELS AT GARAGE 5) FIRE BLOCK MISSING AT DROPPED CEILING IN HALLWAY 6) REVISE PLANS TO SHOW LAUNDRY ROOM MOVED AND CLOSET 7) 1 1/2 VTR NOT ALLOWED TO HAVE 90 DEGREE ELBOWS 8) REVISE PLUMBING ELEC, FRAMING 9) INT. BEAMING WALL MISSING CUT NAILS 10) HTT AT FRONT ENTRY BOLT LOOSE 11) VTR AT KITCHEN 90 DEGREES NOT ALLOWED 12) NAIL PROTECT ELEC WITHIN 1 1/4" FROM EDGE OF STUD STOPPED INSP |