Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM00562


Addresses:

1993 W BRAMBURGH CT

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/08/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) OVERHEAD WATER DISTRIBUTION IS OK. 3) OK FOR DRYWALL.
03/07/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) NO APPROVED PLAN ON SITE.
03/05/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/04/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) AGGREGATE CROSS SECTIONAL AREA OF VENTS THRU ROOF SHALL MEET THE MINIMUN CROSS SECTIONAL AREA OF REQUIRED BLDG SEWER