Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/07/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ADD STUDS STOVE VENT 2) SHIM BLOCKS ADDED UNDER GIRDER TRUSS 3) ADD BLOCKS UNDER GIRDER TRUSS 4) NEED 1" CLEARANCE TO WATER HEATER B-VENT |
|
| 06/06/2005 | FRAMING | Cancelled | CANCELLED PER SUPER | |
| 05/29/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ADD STUDS (MINIMUM 2 X 4) EACH SIDE STOVE HOOD VENT 2) FIREBLOCK TUBS 3) BLOCK REGISTERS HALL BATH 4) ADD BLOCKING BETWEEN FLOORS TO CARRY LOAD OF GIRDER TRUSSES TO SLAB 5) NO PRESSURE HOT WATER SUPPLY 6) EXHAUST FAN LAUNDRY VENT TO OUTSIDE 7) MINIMUM 1" CLEARANCE TO WATER HEATER B-VENT 8) COMPLETE STUCCO MESH |