Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | FRAMING | Approved | IVRS - Inspection :* OK TO INSULATE |
|
| 08/10/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) REFER TO PRIOR NOTES |
|
| 08/05/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) STRAP GLU LAM IN L/R 2) ADD RED HEAD S.E. CORNER LAUNDRY ROOM 3) FIRE BLOCK TUBS 4) STRAP GLU LAM TO FRAMING S.W. CORNER 2ND FLOOR 5) INSTALL FHA STRAPS TOP PLATE IN GARAGE WHERE OVER BORED 6) ADD RECEPTACLE N.W. CORNER OF LOFT 7) NO SUPPLY OR DWV TESTS 8) NEED 12" CLEAR OF PEX TO N.W. CAN LITE KITCHEN 9) NEED 1" CLEARANCE TO FURNACE B-VENTS AND H20 HEATER B-VENT 10) NAIL OFF 1 STUD FRONT WALL 1ST FLOOR 11) REPAIR NEAR WATER LINE |