Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM00535
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/17/2005 | FRAMING | Approved | IVRS - Inspection :* 1) PEX AT CAN LIGHTS HALL WAY |
|
06/15/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) UNSECURED ROMEX LIVING ROOM SHELVES 2) BANG PLATE GARAGE TO PROPERTY LINE 3) PEX AT CAN LIGHTS 4) RAISE VTR EAST BATH 5) BROKEN TRUSS LIVING ROOM SEE MARK ON FLOOR 6) ROMEX MSTR. BATH CEILING NOT SECURED 7) NO GAS TO FIREPLACE 8) #2 SHEAR FRONT BEDROOM-AB'S AT 32" ON CENTER 9) FINISH LATH 10) GAS/H20/DWV-OK |