Permit: T05CM00523

Parcel: 125050760


Addresses:

2416 E 4TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/21/2005 FRAMING Approved IVRS - Inspection :*
06/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK AT REFRIDGERATOR AREA FURR DOWN
2) ADD OUTLET FOR COUNTER AT DISHWASHER SPACE SHOWN ON PLAN
05/26/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO TEST DWV
2) INSTALL BANG PLATES ELECTRIC HOLES WITHIN 1 1/4" STUD FACE
3) NO TEST SEWER SOIL PIPE
4) REPLACE CUT AND OR REMOVE BEARING STUDS
5) INSTALL POSITIVE CONNECTION RAFTERS AT BEARING
6) FIREBLOCK ALL FURR DOWNS
7) ADD SMOKE DETECTORS EXISTING BEDROOMS
8) GAS NOT TO PLAN
9) 10 POUND REQUIRED GAS PIPING
10) INCOMPLETE; STOPPED INSPECTION; COMPLETE ALL AND RECALL