Permit: T05CM00507


Addresses:

1577 W BEANTREE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM00507

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/08/2005 FRAMING Approved IVRS - Inspection :*
07/07/2005 FRAMING Partial Approval IVRS - Inspection :*
1) BLOCK REGISTER AT MASTER
2) SEE #1, 4, 7 AND 8
3) OK TO INSULATE
07/01/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE BLOCK CONCEALLED SPACE AT GARAGE
2) NO TEST ON DWV'S
3) GAS TEST FAILED 0 PSI
4) BLOCK REGISTER AT KITCHEN
5) SMOKE DETECTORS IN MASTER LESS THAN 36" FROM REGISTER
6) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR
7) REMOVE SCREEN FROM DRYER VENT T-TOP
8) FIRE BLOCK CONCEALLED SPACE AT NORTH WINDOWS
9) FRESH AIR DISCONNECTED
10) COMPLY WITH DETAIL 3SD2