Permit: T05CM00505
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 03/08/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) PROVIDE A COMPLETE SET OF REVISED PLANS FOR DUEL TRUND SEWER SYSTEM WITH BACK WATER VALVE 2) REMOVE ALL ABANDONED/DEAD HEADED PLUMBING FROM SEWER SYSTEM |
|
| 03/03/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HAVE PLOT PLAN REVISED FOR HCS LOCATION 2) MANY FITTINGS AND SOIL WET. EXPOSE ALL FITTINGS 3) REMOVE ALL UNECESSARY ABANDONED PLUMBING FROM DBL TRUNK INSTALLATION 4) REMOVE ALL ROCK LARGER THAN 3/4" FROM TRENCH 5) PROVIDE CLEANFILL ON SITE FOR PROPER SHADING TO 6" DEEP |
|
| 03/01/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REQUIRES B.W.V. 2) SEWER LOCATION NOT ON PLOT PLAN 3) STOPPED INSPECTION |