Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM00505
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2005 | FRAMING | Approved | IVRS - Inspection :* | |
06/08/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE APPROVED REPAIR FOR FLOOR TRUSS WEST WALL AND DBL TOP PLATE AT SHEAR TRANSFER WALL 2ND FLOOR 2) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD 3) FIREBLOCK MECH CHASE |
|
06/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS NOT CORRECTED 2) STOPPED INSPECTION |
|
05/26/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLOOR TRUSS WEST WALL LEG REMOVED 2) NAIL PROTECT ELECTRIC WITHIN 1 1/4 FROM EDGE OF STUD 3) SEE INSPECTION DATED 5/20/05 4) STRINGERS HAVE GAPS AT FIRE BLOCKS 5) PROVIDE APPROVED ENGINEER REPAIR FOR DBL TOP PLATE 2ND FLOOR SHEARWALL AND REPLACE SHEAR PANEL 6) FIREBLOCK MECHANICAL CHASE |
|
05/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT MAIN WATER LINES 2) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR 3) PROVIDE 12" OF CLEARANCE FOR WATER LINES FROM CAN LIGHTS 4) NAIL PROTECT 3" ABS AT LAUNDRY 5) REPLACE FLEX DUCT AT KITCHEN, FULL OF WATER 6) NAIL PROTECT WATER LINES AT UPSTAIRS BATH 7) REPAIR DBL TOP PLATE AT SHEAR TRANSFER WALL 2ND FLOOR 8) A/C PLATFORM NOT SUPPORTED |