Permit: T05CM00459

Parcel: 10612017M

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/15/2005 FRAMING Approved IVRS - Inspection :*
07/29/2005 FRAMING Partial Approval IVRS - Inspection :*
1) DEMISING WALLS LINE 16, 15, 14, 11, 10, 9, 6, 5 AND 4
2) INTERIORS 15-16, 15-14, 11-10, 10-9, 6-5 AND 5-4
3) WATER CLOSETS TO BE 16'-18" FROM SIDE WALL PER 2003 ANSI 117.1
4) WHERE IS CODE ANALYSIS ?
5) WALL DETAIL SHOWS DEMISING WALLS TO DECK DOES THAT MEAN 1 HR ? WALLS CURRENTLY TO BOTTOM OF GIRDER. GET ARCHITECT TO PROVIDE CORRECT INFORMATION
06/07/2005 FRAMING Partial Approval IVRS - Inspection :*
05/20/2005 FRAMING Partial Approval IVRS - Inspection :*
1) OK TO PROCEED WITH EXTERIOR SHEATHING
2) GET SCREW TYPE AND SPACING